Committed to Cartoning Machine / Three-dimensional Packaging Machine

0577-66682128

Common Problem

Your Current Location:Home > News Center > Common Problem
How to use the cartoner correctly?
Hits:3195         Date:2019/12/19
1. Connect the power cord, turn on the power switch on the control board, and press the emergency stop switch.
2. Turn on the main power supply of the hot melt adhesive machine, and set the temperature at 150 ~ 180 ℃. (This step is for hot-melt packaging. If it is not spray-sealed, this step can be omitted.)
3. Connect the air source: the air pressure is adjusted at 0.6-0.8MPa
4. Place the paper box: arrange the paper boxes, check whether there is any blocking phenomenon, and stack them neatly in the carton bin. The cartons must be stacked in the same direction with the front side facing up.
4. Through the jog control and other auxiliary button switches, check the parts such as the box opening, feeding, folding angle, and glue spraying to ensure that these important parts are free of debris and operate normally. If problems are found, the relevant technical staff should be notified in time to solve To continue.
5. When the temperature of the hot melt adhesive machine reaches the set temperature, open the "Start" button on the hot melt adhesive machine, and then click the "Start" button on the control panel to start the machine.
6. After the machine is running. Put the material on the conveyor belt to carry out normal packaging production.
Guangdong Hengxinyuan recommends adding lubricating oil to the motorized parts of the cartoner for one month to increase the service life of the machine.